Interface settings

By default, a project can be found on the display that allows to set the interface parameters. This project can be selected at any time via the boot menu. It is important to select the Save setting. How you access the boot menu is described in the Boot menu chapter.



Small/Short "WU" and "LU" versions

Modbus ("WM" and "LM" versions)



On the start page, you can select between two interfaces: network RS-485 or LAN/WIFI. You then access a submenu in which all other settings can be adjusted.

RS-485




The baud rate and the RS-485 or Modbus address can be set in the RS-485 menu. By default, 115,200 baud, 8 data bits, no parity and 1 stop bit are configured.

Network (LAN/WIFI)





In the network settings, you can select whether DHCP is on or off. The port can also be configured.

WIFI





If WiFi is selected as interface, all available networks are scanned and listed at the beginning. The WIFI password is then entered and the module connects to the selected WIFI AP.